Cisco grounding lug

WebOct 1, 2024 · Secure the grounding lug to the chassis grounding pad with two M4 screws, and tighten each screw to 11.5 to 15 in-lb (1.3 to 1.7 N·m) of torque. Step 4 Prepare the other end of the grounding wire and connect it to an appropriate grounding point in your site to ensure an adequate earth ground for the switch. WebNov 26, 2024 · Before you install the Cisco Nexus 7010 chassis into a rack, make sure that you have the following tools and equipment: Mechanical lift capable of lifting 550 pounds (250 kg) Number 1 Phillips screwdriver with …

Cisco Firepower 2100 Series Hardware Installation Guide

WebOct 1, 2008 · 1.Grounding Lug is Supplied as part of accessory kit along with 6500 switch. 2.Grounding wire is not supplied as part of accessory kit along with 6500 switch. 3.The … WebMay 16, 2024 · Crimp the two-hole lug to the ground cable. Line up the holes on the lug with the holes on the ground connection point. Use two 10-32 screws to attach the lug to the ground connection point. (See … flynn unit latrobe regional hospital https://markgossage.org

Hardware Installation Guide for the Cisco 1000 Series …

WebYes, even if it's racked. Screws corrode, oils and dirt can break continuity. Incidental contact for grounding is a bad. That's why the ground on plugs is a hair longer than the conductors. Ground is important. ESD is bad. Attach to closest ground (ESD discharge on a UPS, or a pipe, or ground wire, or rack lug). WebFeb 1, 2024 · Strip one end of the ground wire to the length required for the terminal. Step 3: Crimp the ground wire to the grounding lug using the wire crimper. Step 4: Attach the grounding lug (1) to the chassis using the screws set aside in step 1. Tighten the screw to a torque of 8 to 10 inch-pound (0.9 to 1.1 newton meter). WebFeb 16, 2024 · Perform the following procedure to ground the Cisco ASR 903 Router using a 2-hole lug and the corresponding mounting point. Most carriers require a minimum 6 AWG ground connection. Verify your carrier’s requirements for the ground connection. Procedure Installing the Fan Tray flynn\u0027s wrecking yard for sale

Cisco ASR 903 and ASR 903U Aggregation Services Router …

Category:Hardware Installation Guide for Cisco 8200 Series Routers

Tags:Cisco grounding lug

Cisco grounding lug

Cisco MDS 9396S Multilayer Fabric Switch Hardware Installation …

WebFeb 26, 2024 · Crimp the grounding wire in the barrel of the grounding lug. Verify that the ground wire is securely attached to the ground lug. Step 4: Place the grounding wire lug against the grounding pad, … WebAug 7, 2024 · Dual-hole ground lug and two screws (included in the DC power supply accessory kit) and single-hole ground lug and screw (included in the switch accessory kit). ... If you contact Cisco Technical …

Cisco grounding lug

Did you know?

WebOct 25, 2024 · The ground lug of the NCS 2015 AC shelf must be permanently connected to ground. The single ground lug must be a dual-hole type, UL Listed, CSA certified and rated to accept the #4 AWG … WebFeb 24, 2024 · A grounding pad with two threaded holes is provided on the chassis for attaching either a grounding lug or grounding plate. The ground lug must be NRTL-listed. In addition, a copper conductor (wires) …

WebOct 27, 2024 · Attach the Grounding Lug Step 6: Make sure that the lug and cable do not interfere with other equipment. Step 7: Prepare the other end of the grounding cable … WebSecure the grounding lug to the chassis with two M4 screws. Ensure that the grounding lug and the grounding wire will not interfere with other switch hardware or rack …

WebThe City of Fawn Creek is located in the State of Kansas. Find directions to Fawn Creek, browse local businesses, landmarks, get current traffic estimates, road conditions, and … WebJan 11, 2024 · For the ground lug—approximately 0.75 inch (20 mm) For user-provided ring terminal—as required. Step 2: Crimp the ground wire to the ground lug or ring terminal, using a crimp tool of the appropriate size. Step 3: Attach the ground lug or ring terminal to the chassis as shown in Chassis Grounding section. For a ground lug, use the two ...

WebMar 27, 2024 · One ground lug #6 AWG, 90 degree, #10 post (part number 32-0608-01) Two 10-32 x 39-8-inch Phillips Head screws (part number 48-0700-01) ... Cisco Secure Firepower 4100. This document has a URL …

http://www.gulfstreamdata.com/32-grounding-lugs/view-all-products.html flynn victoriaWebMar 17, 2024 · Grounding lug — When using the double-hole lug connector provided with the system, the ground wire must be 6 AWG only. Otherwise, a supported closed-loop ring connector must be used for 8-14 AWG wire. Grounding screws — Two M4.0 x 8mm Phillips pan-head screws. Supplied as part of the accessory kit. flynn veterinary clinic lakeview orWebJul 1, 2024 · For grounding the chassis, use size 14 AWG copper wire and the ground lug. These are not a part of the accessory kit. Use the UNC 6-32 screws, which have a length of about 0.25 inches. To install the … green pants and brown bootsWebSep 8, 2024 · Grounding cable (6 AWG recommended), sized according to local and national installation requirements; the required length depends on the proximity of the Cisco Nexus FEX to proper grounding facilities Crimping tool large enough to accommodate girth of lug Wire-stripping tool Unpacking and Inspecting the Cisco Nexus Fabric Extender flynn veterinary clinicWebThe Cisco ASR 1006 Router requires a minimum of 6 rack units (10.45 inches or 26.6 cm) of vertical rack space. Measure the proposed rack location before mounting the chassis … green pantry troutWebAug 17, 2024 · Grounding cable (6 AWG recommended), sized according to local and national installation requirements; the required length depends on the proximity of the switch to proper grounding facilities Crimping tool large enough to accommodate the girth of the lug Wire-stripping tool Unpacking and Inspecting the Switch greenpantswearingguy gmail.comWebJan 24, 2008 · For information on chassis grounding on Cisco 1700 series routers, see the hardware installation guide for your router. Cisco 2600 Series, Cisco 3600 Series, and Cisco 3700 Series Routers ... The Cisco ICS 7750 chassis has a grounding lug that needs to be properly connected using a green and yellow 14 American Wire Gauge (AWG) … flynn vets ballynahinch